Flexible and diverse size options: 4 sizes are available to suit different project require...
With its excellent design and functionality, VENUS provides users with an efficient and convenient use experience. Its gear compartment and gear tray can be easily opened and replaced without tools, which greatly simplifies the maintenance process and makes the daily maintenance of the equipment more efficient and convenient. This design not only reduces maintenance costs, but also increases the service life of the equipment.
The application of optical lenses makes the light distribution more uniform and soft, avoids glare problems, and achieves the effect of asymmetric light distribution. This design is particularly suitable for scenes that require precise light control, such as road lighting or industrial lighting, ensuring efficient use of light and visual comfort.
VENUS uses a high-pressure die-cast aluminum body and is coated with a corrosion-resistant polyester powder coating, which makes it extremely durable and corrosion-resistant. This material combination not only enhances the appearance and texture of the product, but also ensures its long-term stable operation in harsh environments.
In terms of heat dissipation, VENUS is equipped with a durable heat sink, which effectively reduces the temperature of the equipment during operation and extends its service life through optimized thermal management design. This efficient heat dissipation performance is particularly important for high-power LED drivers, ensuring the stability and reliability of the equipment during long-term operation.
MAIN APPLICATIONS
![]() ROAD & HIGHWAY |
![]() BRIDGES |
![]() URBAN & RESIDENTIAL AREAS |
![]() SQUARE & PEDESTRIAN AREAS |
TECHNICAL SPECIFICATIONS
| SPEC | ![]() S |
![]() M |
![]() L |
![]() XL |
![]() XXL |
| Wattage | 60-100w | 80-200w | 150-250w | 200-300w | 200-400w |
| Input voltage | 100-277V/50-60Hz | ||||
| Color temperature | 3000-6500K | ||||
| Color rendering index |
CRI>70 | ||||
| Operating temperature |
-40℃~+50℃ | ||||
| Housing material | ADC12 | ||||
| Ingress protection | IP66 | ||||
| Impact strength | IK08 | ||||
| Surge protection | 10KV/20KV | ||||
| Diffuser | Tempered glass | ||||
| Spigot diameter | 60mm | ||||
| Weight | 5.8kg | 7.2kg | 8.9kg | 10.5kg | 13.1kg |
DESIGN IN DETAILS
![]() Tool-less opening of gear compartment. |
![]() Large cooling fins withstand high temperature. |
![]() Fixation part for universal Φ42-60mm side entry mounting. |
![]() Optional with NEMA socket & photocell/shorting cap. |
OPTICS AVAILABLE
DIMENSIONS (mm)
| MODEL | Length(L) | Width(W) | Height(L) |
| VENUS S | 422mm | 320mm | 140mm |
| VENUS M | 522mm | 320mm | 140mm |
| VENUS L | 600mm | 320mm | 140mm |
| VENUS XL | 725mm | 320mm | 140mm |
| VENUS XXL | 853mm | 320mm | 140mm |
ORDER INFORMATION
| Order code | LED type | LED Qty | Optics Qty |
Rated Wattage | Luminaire efficiency up to |
Luminous flux | CCT | CRI |
| VNS101 | 3030 | 96 | 2 | 60w | 120lm/w | 7200lm | 3000K-6500K | >70 |
| VNS102 | 3030 | 144 | 3 | 100w | 120lm/w | 12000lm | 3000K-6500K | >70 |
| VNS201 | 3030 | 144 | 3 | 100w | 120lm/w | 12000lm | 3000K-6500K | >70 |
| VNS202 | 3030 | 192 | 4 | 150w | 120lm/w | 18000lm | 3000K-6500K | >70 |
| VNS203 | 3030 | 240 | 5 | 200w | 120lm/w | 24000lm | 3000K-6500K | >70 |
| VNS301 | 3030 | 192 | 4 | 150w | 120lm/w | 18000lm | 3000K-6500K | >70 |
| VNS302 | 3030 | 240 | 5 | 200w | 120lm/w | 24000lm | 3000K-6500K | >70 |
| VNS303 | 3030 | 288 | 6 | 250w | 120lm/w | 30000lm | 3000K-6500K | >70 |
| VNS401 | 3030 | 288 | 6 | 250w | 120lm/w | 30000lm | 3000K-6500K | >70 |
| VNS402 | 3030 | 336 | 7 | 300w | 120lm/w | 36000lm | 3000K-6500K | >70 |
| VNS403 | 3030 | 384 | 8 | 300w | 120lm/w | 36000lm | 3000K-6500K | >70 |
| VNS501 | 3030 | 384 | 8 | 300w | 120lm/w | 36000lm | 3000K-6500K | >70 |
| VNS502 | 3030 | 480 | 10 | 400w | 120lm/w | 48000lm | 3000K-6500K | >70 |
| Remark: - Wattage can be customized upon project request. - Standard housing painting color light grey; other color can be painted upon request. |
||||||||
LOGISTICS DATA
| MODEL | Packing unit (pcs/carton) |
Carton size(mm) (Length*Width*Height) |
Net weight | Gross weight | Volume |
| VENUSS | 1 | 520*390*220mm | 5.8kg | 6.7kg | 44.6dm³ |
| VENUSM | 1 | 620*390*220mm | 7.2kg | 8.2kg | 53.2dm³ |
| VENUSL | 1 | 700*390*220mm | 8.9kg | 10.0kg | 60.1dm³ |
| VENUSXL | 1 | 820*390*220mm | 10.5kg | 11.8kg | 70.4dm³ |
| VENUSXXL | 1 | 960*390*220mm | 13.1kg | 14.6kg | 82.4dm³ |

INSTALLATION & MAINTENANCE
Experience
Through precision optics, intelligent controls, and energy-saving innovations, we create tailored lighting solutions that transform spaces, enhance functionality, and optimize energy consumption. Serving industries worldwide, we illuminate smart cities, industrial complexes, commercial spaces, and premium residential environments.
We don’t just provide lighting—we engineer illumination experiences that redefine efficiency, aesthetics, and sustainability.
A distribution center in Ohio replaced 42 metal-halide floodlights around its truck yard with modular LED flood lights in May 2026. Connected load dropped from 21.8 kW to 8.4 kW, and average pavement illuminance rose from 38 lux to 92 lux. Fourteen...
A suspension bridge pylon standing 180 m above the water line is one of the harshest mounting positions in public lighting. Salt-laden wind, traffic-induced vibration, and a 40°C seasonal temperature swing will destroy a commercial-grade fixture in...
A 40,000-square-foot distribution center typically runs sixty to eighty high bay fixtures. If those are 400W metal halide units, the lighting load alone draws about 28 kW. At 12 hours per day and the US commercial average of $0.12 per kWh, that loa...
A yard lighting specification is not a light fixture specification. A 400 W LED flood light mounted at 10 m on a steel pole will not necessarily deliver the lux value printed on its datasheet. Beam angle, mounting height, pole spacing and aiming al...